Thermographic analysis of temperature rise in the pulp chamber with LED and QTH light curing units: An in vitro investigation


Department of Conservative Dentistry and Endodontics, Tamilnadu Government Dental College and Hospital, Chennai, Tamil Nadu, India

Correspondence Address:
S Uma Maheswari
Flat No. 004, Manish Residency, 28th Main, Sarakki, J.P. Nagar 6th, Phase, Bangalore - 560 078
India
Login to access the Email id


DOI: 10.4103/0976-433X.116820

Rights and Permissions

Aims: To compare the temperature rise in the pulp chamber with light-emitting diode (LED) and Quartz-Tungsten-Halogen (QTH) light curing units by infrared thermography. Materials and Methods: Class V cavity was prepared in 20 freshly extracted maxillary first premolars measuring 2 mm depth, 4 mm width, and 1 mm above the cement enamel junction. The samples were divided into two groups (n = 10). Cavity was etched with 37% phosphoric acid, rinsed and bonding agent was applied over the etched cavity surface on both the groups. In group I the samples were cured with LED curing unit, whereas group II were cured with QTH unit, which was followed by two incremental curing of composite. Thermal emission for QTH and LED (fast mode) light curing units were noted by Fluke Ti32 infrared thermography after 20 s bonding agent curing and first and second increment composite curing for 40 s each. Statistical Analysis: Data were analyzed with Student t-test and Friedman test using SPSS version 11.5 software. Results: The statistical analysis revealed that the temperature rise was significantly minimal with LED fast mode (Group I) in all stages of curing compared with QTH unit (Group II). There is significant rise of temperature during first incremental curing of composite, whereas insignificant increase of temperature during curing of second increment of composite (P < 0.001%). Conclusions: Temperature rise caused due to both QTH and LED light curing units does not result in irreversible pulpal damage and thermography is a viable means of quantifying the temperature changes during photo polymerization.


[FULL TEXT] [PDF]*
Print this article     Email this article
Next article
Previous article
Table of Contents

Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Citation Manager
Access Statistics
Reader Comments
Email Alert*
Add to My List*
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1892    
    Printed44    
    Emailed0    
    PDF Downloaded246    
    Comments [Add]    
    Cited by others 3    

Recommend this journal